6
Introduction
LED Display - Alarm Settings
By default, the Koolance audio alarm will sound if the primary sensor reaches
55ºC (131ºF). When the system alarm sounds, the LED temperature will ash in
the display and the radiator fans will increase to 100% power.
To change this setting with the LED Display, press and hold + together for
3 seconds. The alarm temperature will begin ashing. You may change this value
from 0ºC (32ºF) up to 99ºC (210ºF). The normal temperature reading will resume
if you do not press any buttons for 4 seconds.
To reset the temperature alarm to the default (55ºC / 131ºF) setting, press and
hold the ºC/F button until “dEF” ashes in the display. NOTE: This will also reset
the fan speed mode to “auto”.
Auto Mode Manual Mode Fan Power % Total CFM Fan RPM
0 - 35ºC (32 - 95ºF) 1 30 84 720
36 - 37ºC (97 - 99ºF) 2 35 99 840
38 - 39ºC (100 - 102ºF) 3 40 114 960
40 - 41ºC (104 - 106ºF) 4 45 129 1080
42 - 43ºC (108 - 109ºF) 5 50 141 1200
44 - 45ºC (111 - 113ºF) 6 60 171 1440
46 - 47ºC (115 - 117ºF) 7 70 198 1680
48 - 49ºC (118 - 120ºF) 8 80 225 1920
50 - 51ºC (122 - 124ºF) 9 90 255 2160
52 - 99ºC (126 - 210ºF) 10 100 282 2400
Details on fan modes are as follows: